Hardware pinouts information and cables schemes

Avocent / Cybex / BlackBox XPSI and KV1609C serial control cards RJ45 pinout

connector wiring scheme

bookmark this page

connector of the 4XP / XP4000 / XP4040 / ServSwitch Multi EXP

8 pin RJ45 (8P8C) female connector layout

8 pin RJ45 (8P8C) female connector
at the rear of the XPSI card



There are a total of four (4) RJ45 ports on the card numbered from 1 to 4. The topmost port is one (1). This information applies to the rebranded BlackBox card KV1609C Serial Control Card. The information relates to the Avocent/Cybex 4XP/XP4000/XP4040 chassis and the BlackBox ServSwitch Multi EXP chassis.
rear of the XPSI card.
Pin
Name Direction Description
1 DTR Data Terminal Ready
2 RTS Request to Send
3 GND Signal Ground
4 TXD Transmitted Data
5 RXD Received Data
6 GND Signal Ground
7 CTS Clear to Send
8 DSR Data Set Ready


This information should be correct, but may be not. Please, help us to improve this document!
Is this document CORRECT or INCORRECT? Your opinion will be used to establish document status (showed at the bottom).
Pinouts.ru > Some peripheral devices pinouts >  Pinout of Avocent / Cybex / BlackBox XPSI and KV1609C serial control cards RJ45 and layout of 8 pin RJ45 (8P8C) female connector
Document status: correct
Source(s) of this and additional information: Avocent/Cybex
Contributor: Chris Romero
1 reports
Last updated at Fri Aug 19 2005. Submit additions or corrections for this document. Is this document correct or incorrect? What is your opinion?
[Discuss at the forum] [Back to index] [SUBMIT new pinout]
This page contain parts under Copyright © 2000-2007 by pinouts.ru team.
No any portion of this webpage may be reproduced in any form without visible direct link to this page provided. Webmaster permission required in any other cases.
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.
7138 hits since August 13, 2005