Hardware pinouts information and cables schemes

Cyclades cabling diagrams pinout

serial interface cable

bookmark this page



DB-25 to DB-25, straight-thru

 DB-25                  DB-25
 M / F                  M / F
--------              --------
 2   TxD ------------ TxD    2
 3   RxD ------------ RxD    3
 7   Gnd ------------ Gnd    7
20   DTR ------------ DTR   20
 6   DSR ------------ DSR    6
 8   DCD ------------ DCD    8
 4   RTS ------------ RTS    4
 5   CTS ------------ CTS    5

DB-25 to DB-25, crossover

 DB-25                  DB-25
 M / F                  M / F
--------              --------
 2   TxD ------------ RxD   3
 3   RxD ------------ TxD   2
 7   Gnd ------------ Gnd   7

20   DTR --------|--- DSR   6
                 |--- DCD   8

 6   DSR ---|-------- DTR   20
 8   DCD ---|

 4   RTS ------------ CTS   5
 5   CTS ------------ RTS   4
 

DB-25 to DB-9, straight-thru

 DB-25                  DB-9
 M / F                  M / F
--------              --------
 2   TxD ------------ TxD    3
 3   RxD ------------ RxD    2
 7   Gnd ------------ Gnd    5
20   DTR ------------ DTR    4
 6   DSR ------------ DSR    6
 8   DCD ------------ DCD    1
 4   RTS ------------ RTS    7
 5   CTS ------------ CTS    8

DB-25 to DB-9, crossover

 DB-25                  DB-9
 M / F                  M / F
--------              --------
 2   TxD ------------ RxD   2
 3   RxD ------------ TxD   3
 7   Gnd ------------ Gnd   5

20   DTR --------|--- DCD   1
                 |--- DSR   6

 6   DSR ---|-------- DTR   4
 8   DCD ---|

 4   RTS ------------ CTS   8
 5   CTS ------------ RTS   7

RJ-45 (Cyclades) to DB-25, straight-thru


 RJ-45                  DB-25
Cyclades                M / F
--------              --------
 3   TxD ------------ TxD    2
 6   RxD ------------ RxD    3
 4   Gnd ------------ Gnd    7
 2   DTR ------------ DTR   20
 8   DSR ------------ DSR    6
 7   DCD ------------ DCD    8
 1   RTS ------------ RTS    4
 5   CTS ------------ CTS    5

RJ-45 (Cyclades) to DB-25, crossover

 RJ-45                  DB-25
Cyclades                M / F
--------              --------
 3   TxD ------------ RxD   3
 6   RxD ------------ TxD   2
 4   Gnd ------------ Gnd   7

 2   DTR --------|--- DSR   6
                 |--- DCD   8

 7   DCD ---|-------- DTR   20
 8   DSR ---|

 1   RTS ------------ CTS   5
 5   CTS ------------ RTS   4

RJ-45 (Cyclades) to DB-9, straight-thru

 RJ-45                  DB-9
Cyclades                M / F
--------              --------
 3   TxD ------------ TxD    3
 6   RxD ------------ RxD    2
 4   Gnd ------------ Gnd    5
 2   DTR ------------ DTR    4
 8   DSR ------------ DSR    6
 7   DCD ------------ DCD    1
 1   RTS ------------ RTS    7
 5   CTS ------------ CTS    8

RJ-45 (Cyclades) to DB-9, crossover

 RJ-45                  DB-9
Cyclades                M / F
--------              --------
 3   TxD ------------ RxD   2
 6   RxD ------------ TxD   3
 4   Gnd ------------ Gnd   5

 2   DTR --------|--- DCD   1
                 |--- DSR   6

 7   DCD ---|-------- DTR   4
 8   DSR ---|

 1   RTS ------------ CTS   8
 5   CTS ------------ RTS   7

RJ-45 (Cyclades) to RJ-45 (Cyclades), straight-thru

 RJ-45                 RJ-45 
Cyclades              Cyclades 
--------              --------
 3   TxD ------------ TxD    3
 6   RxD ------------ RxD    6
 4   Gnd ------------ Gnd    4
 2   DTR ------------ DTR    2
 8   DSR ------------ DSR    8
 7   DCD ------------ DCD    7
 1   RTS ------------ RTS    1
 5   CTS ------------ CTS    5

RJ-45 (Cyclades) to RJ-45 (Cyclades), crossover

 RJ-45                 RJ-45 
Cyclades              Cyclades 
--------              --------
 3   TxD ------------ RxD   6
 6   RxD ------------ TxD   3
 4   Gnd ------------ Gnd   4

 2   DTR --------|--- DCD   7
                 |--- DSR   8

 7   DCD ---|-------- DTR   2
 8   DSR ---|

 1   RTS ------------ CTS   5
 5   CTS ------------ RTS   1

RJ-45 (Cyclades) to RJ-45 (Sun/Cisco), straight-thru

 RJ-45                  RJ-45 
Cyclades              Sun/Cisco
--------              ---------
 3   TxD ------------ TxD    3
 6   RxD ------------ RxD    6
 4   Gnd --------|--- Gnd    4
                 |--- Gnd    5
 2   DTR ------------ DTR    2
 7   DCD ------------ DSR    7
 1   RTS ------------ RTS    1
 5   CTS ------------ CTS    8

RJ-45 (Cyclades) to RJ-45 (Sun/Cisco), crossover

 RJ-45                  RJ-45 
Cyclades              Sun/Cisco
--------              ---------
 3   TxD ------------ RxD    6
 6   RxD ------------ TxD    3
 4   Gnd --------|--- Gnd    4
                 |--- Gnd    5
 2   DTR ------------ DSR    7
 7   DCD ------------ DTR    2

 1   RTS ------------ CTS    8
 5   CTS ------------ RTS    1

RJ-45 (Cyclades) to MMJ (DEC), crossover

 RJ-45                   MMJ 
Cyclades                 DEC
--------              ---------
 3   TxD ------------ RxD    5
 6   RxD ------------ TxD    2
 4   Gnd --------|--- Gnd    3
                 |--- Gnd    4
 2   DTR ------------ DSR    6
 7   DCD ------------ DTR    1

DB-9 to DB-9, crossover

 DB-9                  DB-9
 M / F                 M / F
--------              --------
1 ----+--------- 4 (1 and 6 to 4)
6 ----+
2 -------------- 3 (2 connected to 3)
3 -------------- 2 (3 connected to 2)
4 --------+----- 1 (4 connected to 1 and 6)
          +----- 6
5 -------------- 5 (5 connected to 5)
7 -------------- 8 (7 connected to 8)
8 -------------- 7 (8 connected to 7)


This information should be correct, but may be not. Please, help us to improve this document!
Is this document CORRECT or INCORRECT? Your opinion will be used to establish document status (showed at the bottom).
Pinouts.ru > Serial interfaces cables and converters schemes listing >  Pinout of Cyclades cabling diagrams and layout of 8 pin RJ45 (8P8C) male connector and 9 pin D-SUB female connector
Document status: unknown
Source(s) of this and additional information: www.cyclades.de 0 reports
Last updated at Wed Aug 15 2007. Submit additions or corrections for this document. Is this document correct or incorrect? What is your opinion?
[Discuss at the forum] [Back to index] [SUBMIT new pinout]
This page contain parts under Copyright © 2000-2007 by pinouts.ru team.
No any portion of this webpage may be reproduced in any form without visible direct link to this page provided. Webmaster permission required in any other cases.
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.
8541 hits since October 27, 2006