Hardware pinouts information and cables schemes

Cisco X.21 DTE cable (DB-60 to DB-15) pinout

serial interface cable

bookmark this page

This document describes the X.21 cable assembly and pinouts (Data Terminal Equipment - DTE). Cisco Part#: CAB-X21MT=



60 Pin1 Signal Description Direction 15 Pin Signal
J1-48
J1-47
GND
MODE_2
Shorting group---
J1-51
J1-52
GND
MODE_DCE
Shorting group---
J1-46Shield_GNDSingle-J2-1Shield GND
J1-11
J1-12
TxD/RxD+
TxD/RxD-
Twisted pair no. 3-
-
J2-2
J2-9
Transmit+
Transmit-
J1-9
J1-10
RTS/CTS+
RTS/CTS-
Twisted pair no. 2-
-
J2-3
J2-10
Control+
Control-
J1-28
J1-27
RxD/TxD+
RxD/TxD-
Twisted pair no. 6-
-
J2-4
J2-11
Receive+
Receive-
J1-1
J1-2
CTS/RTS+
CTS/RTS-
Twisted pair no. 1-
-
J2-5
J2-12
Indication+
Indication-
J1-26
J1-25
RxC/TxCE+
RxC/TxCE-
Twisted pair no. 5-
-
J2-6
J2-13
Timing+
Timing-
J1-15
Shield
Control_GND
-
Twisted pair no. 4-
-
J2-8
Shield
Control GND
-

Arrows indicate signal direction: - indicates DTE to DCE, and - indicates DCE to DTE.

1 Any pin not referenced is not connected.


This information should be correct, but may be not. Please, help us to improve this document!
Is this document CORRECT or INCORRECT? Your opinion will be used to establish document status (showed at the bottom).
Pinouts.ru > Serial interfaces cables and converters schemes listing >  Pinout of Cisco X.21 DTE cable (DB-60 to DB-15) and layout of 60 pin Cisco DB connector and 15 pin Cisco DB connector
Document status: unknown
Source(s) of this and additional information: Cisco Systems, Inc. and Technick.net 1 reports
Last updated at Sat Jun 25 2005. Submit additions or corrections for this document. Is this document correct or incorrect? What is your opinion?
[Discuss at the forum] [Back to index] [SUBMIT new pinout]
This page contain parts under Copyright © 2000-2007 by pinouts.ru team.
No any portion of this webpage may be reproduced in any form without visible direct link to this page provided. Webmaster permission required in any other cases.
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.
9485 hits since March 4, 2005