Hardware pinouts information and cables schemes

APC BackUPS ES (old) cable wiring pinout

connector or cable wiring

bookmark this page

APC part # 940-0119A



The BackUPS ES has a straight through serial cable with no identification on the plugs.

     computer           ----------- BackUPS-ES -----------------
     DB9-M              DB-9F
     pin    signal      pin
     
      4      DSR   ->    4 --+
                             |  diode   resistor
      6      DTR   ->    6 --+---->|----/\/\/\---o kill power
     
      1      DCD   <-    1 --+
                             |
      2      RxD   <-    2 --+----------------+--o low battery
                                              |
      7      RTS   ->    7 --------+--/\/\/\--+
                                   |
                                   +--/\/\/\--+
                                              |
      8      RI    <-    8 --+----------------+--o on battery
                             |
      9      CTS   <-    9 --+
     
      5      GND   ---   5 ----------------------o ground
     
      3      TxD         3 nc


This information should be correct, but may be not. Please, help us to improve this document!
Is this document CORRECT or INCORRECT? Your opinion will be used to establish document status (showed at the bottom).
Pinouts.ru > GPS, UPS, Switches and other devices cables and adapters schematics >  Pinout of APC BackUPS ES (old) cable wiring and layout of 9 pin D-SUB male connector and 9 pin D-SUB male connector
Document status: unknown
Source(s) of this and additional information: www.apcupsd.com
Contributor: William Stock
0 reports
Last updated at Thu Jan 10 2008. Submit additions or corrections for this document. Is this document correct or incorrect? What is your opinion?
[Discuss at the forum] [Back to index] [SUBMIT new pinout]
This page contain parts under Copyright © 2000-2007 by pinouts.ru team.
No any portion of this webpage may be reproduced in any form without visible direct link to this page provided. Webmaster permission required in any other cases.
Efforts have been made to ensure this page is correct, but it is the responsibility of the user to verify the data is correct for their application.
81 hits since January 10, 2008