APC Dumb UPS cable (simple) pinout |
connector or cable wiring |
APC Part# 940-0020 (grey cable). Should work with APC PowerChute Plus software.
9 pin D-SUB male connector | This cable can only be used on voltage-signalling UPSes, and provides the On Battery signal as well as kill UPS power (and may be Low Battery signal).
APC Part# - 940-0020B (investigated by apcupsd team) Signal Computer UPS DB9F DB9M CTS 8 -------------------- 2 On Battery DTR 4 -------------------- 1 Kill power GND 5 ---------------*---- 4 Ground | --- *---- 9 Common DCD 1 ----|///|----------- 5 Low Battery |\\\| RTS 7 ----|///| (probably a --- semi-conductor)Note: sides swapped. Full scheme of 940-0020C isn't yet known. APC Part# - 940-0020C (investigated by apcupsd team) Signal Computer UPS DB9F DB9M CTS 8 -------------------- 2 On Battery DTR 4 -------------------- 1 Kill power GND 5 ---------------*---- 4 Ground | *---- 9 Common RTS 7 -----[ 93.5K ohm ]----- 5 Low Battery or semi-conductor Our users reports that the 20C is designed to mimic a mouse movement when it received an on battery signal from the Back-UPS. Therefore the computer will wake up and shutdown properly. The 20B cable does not have this functionality. | 9 pin D-SUB female connector | ||||||||||||||||
Pinouts.ru > GPS, UPS, Switches and other devices cables and adapters schematics > Pinout of APC Dumb UPS cable (simple) and layout of 9 pin D-SUB male connector and 9 pin D-SUB female connector |
correct | |
Source(s) of this and additional information: www.apcupsd.com, UPS FAQ in russian | 7 reports | |
Last updated at Thu Jan 10 2008. Submit additions or corrections for this document. | Is this document correct or incorrect? What is your opinion? |