Hardware pinouts information and cables schemes

RS232 to TTL serial cable pinout

interface converter

bookmark this page

i.e. this cable may be used for wiring cellular phone to PC



universal mobile cellular cable or data-cable

Microcontrollers serial port (often called a SCI, COM, or ASYNC port) often do not generate the proper voltages required for connecting to computer RS-232 serial port. In this case special converter needed. Most microcontrollers run on a single supply voltage, that is usually +5 volts. In rough terms, logical 1 on these devices indicates that +5 is the voltage on the output pin. Logical 0 specifies that 0 volts is on the line.

The RS-232-C standard specifies that the voltage on the wire for sending a logical 0 are from +5v to +15v. The voltage for sending a 1 are from -5v to -15v. Most microcontrollers not capable of generating these voltages. So, to connect a microcontroller serial port to a true RS-232 device, you need to convert the TTL voltages of 0 and +5 into voltages between about -10 volts and +10 volts.

MAX232 is the chip that makes this work for you. It runs on a single chip supply (+5 volts), contains double charge pump voltage doubler and a +10v to -10v voltage inverter and requires a few external capacitors. There are some versions of this chip. The voltages output are used to generate the RS-232 compliant signals of two serial ports on the same physical package.

UNKNOWN connector
at the device like a cellular phone
Pinouts.ru > Convert one interface to another cables schemes listing >  Pinout of RS232 to TTL serial cable and layout of 9 pin D-SUB male connector
Document status: correct
4 reports
Last updated at Fri Mar 24 2006. Submit additions or corrections for this document. Is this document correct or incorrect? What is your opinion?
[Discuss at the forum] [Back to index] [SUBMIT new pinout]