============================================================================= AST RESEARCH, INC. TECHNICAL BULLETIN #0783B 01-11-93 ============================================================================= POWER EXEC WITH FILE TRANSFER AND LAPLINK SOFTWARE Time-out problems have been reported during file transfers when running Laplink version 3.00 on the AST Power Exec product in the maximum battery life power management mode. These problems can be resolved by changing the Power Exec's Power Management mode to "Max Performance" during file transfers. The problem can also be resolved by upgrading the Laplink software to version 3.00A or to Laplink Pro. Contact Traveling Software for information regarding Laplink software. The recommended file transfer method between your Power Exec and other computer systems is the supplied utility INTERLINK.EXE and INTERSRV.EXE. Other programs utilize communication methods which often disrupt the Power Exec's Intelligent Power Management by attempting to directly control hardware components.