============================================================================= AST RESEARCH, INC. TECHNICAL BULLETIN #0779 09-25-92 ============================================================================= PREMIUM SE 4/33 AND MAYNARD INTERNAL TAPE ADAPTER PROBLEM: When using a Maynard (2000 DAT) Tape Backup with a 16-bit internal Maynard SCSI adapter the system hangs. CAUSE: The problem is caused by the Maynard SCSI controller cards (part number 08-9-6010000 revision 3) that uses an AMD 33C93 chip at location U12. This chip generates noise which results in an un-requested interrupt causing a system hang. Maynard controllers shipping with a WD 33C93A chip at location U12 do not have this problem. AFFECTED SYSTEMS: Premium SE and Premium TE systems with EISA motherboards (part number 202377-00X). SOLUTION: Contact Maynard Technical Support at 800-227-6296 for further information and resolution.