============================================================================= AST RESEARCH, INC. TECHNICAL BULLETIN #0769A 11-10-92 ============================================================================= AST SVGA 14" LOW RADIATION MONITOR PROBLEM: When using the 1024x768 mode on the SVGA 14" low radiation monitor, the picture will shift to the left. CAUSE: This is due to a timing issue within the monitor itself. AFFECTED SYSTEMS: SVGA 14" low radiation monitor part number 500902-XXX revision A. SOLUTION: Replace revision A monitor with a revision B monitor part number 500902-001, 002, or 003. NOTE: The part number 500902-XXX on the packing box will remain revision A. However, the part number on the monitor itself will change to 230253- XXX revision B.