============================================================================== AST RESEARCH, INC. TECHNICAL BULLETIN #0665 02-14-91 ============================================================================== GUIDELINES FOR USING NOVELL'S COMPSURF UTILITY The following are some general guidelines that should be followed when using Novell's compsurf utility: NEVER use the format option in COMPSURF when: - Using a SCSI drive. - Using a drive over 1024 cylinders. - Using a WD1007A-XXX hard drive controller. - Hard drive manufacturer forbids it. To successfully prepare a hard drive (over 1024 cylinders) for Novell, do the following: - Set drive type in CMOS per manufacturers recommendations. - Low-level format using the manufacturers format utility (i.e., HDFORMAT for an AST drive). - If the drive requires the Novell compsurf "stamp", run compsurf but DO NOT take the format option. - As soon as the compsurf utility starts, it will check track 0. Immediately after the track 0 test is completed (usually within 45 seconds), hit the ALT + F10 keys twice. This should stop the compsurf utility and "stamp" the drive.