============================================================================= AST RESEARCH, INC. TECHNICAL BULLETIN #0661 01-30-91 ============================================================================= AST COAX II-CUT AND WD-1007A CONTROLLER CONFLICT A Coax Adapter Board (CAB) Error 9 may occur while trying to load the AST COAX II-Cut Emulation software. (Reference Technical Bulletin #0453: Error 9 is defined as "Reserved".) Any error that is listed as "Reserved" typically is the result of a hardware conflict between an AST card and another card in the machine. The specifications for a Western Digital WD-1007A ESDI Controller states that it uses a shared memory address of C800H. Western Digital has indicated that a potential problem may occur. To resolve this problem, move Jumper W1 on the controller from 2-3 to 1-2.